PDF

FS18OHH2R18 300/500 V

Power, controls and signaling cables with Al/Pet tape and red copper braid shield, fire retardant and low halogens emission

  1. Conductor
  2. Insulation
  3. Shield
  4. Sheath

Cca-s3,d1,a3

APPLICATION: For sections smaller than 1.5mmq, they are suitable for the transmission of signals and commands for the interconnection of instrumentation and control systems with digital or analog signal transmission. For larger sections, they are suitable for energy transport and the transmission of signals and controls intended for interconnection between parts of construction machines, equipment generally including machine tools, where a certain level of protection against electromagnetic interference ( Copper braid) and electrostatic (aluminum / polyester tape). In environments that do not face with high risk of fire as buildings intended for civil use, with a fire height less than 24 m, waiting room, bar, restaurant, medical studio. (Low risk - bunch laying )

INSTALLATION: For fixed indoor installation in dry or wet environments and temporarily outdoor. They can be installed in cable trays, pipes, conduits and similar systems. Not for direct burial..

FEATURESDESCRPTIONSTANDARDS
Conductors: annealed red copper CEI EN 60228 (Tab.9)
Insulation: PVC, S18 quality CEI 20-11/0-1 (CEI EN 50363)
Cores colour: UNEL 00722 or Black numbered UNEL 00722
Shield: Al/Pet tape
Shield: braid of annealed red copper
Sheath: PVC, R18 quality CEI 20-11/0-1 (CEI EN 50363)
Sheath colour: Brown RAL 8003
Low halogen emission: (< 22%) CEI EN 50267-2-1 - IEC 60754-1
Oil resistant: CEI 20-34/0-1
DC resistance: CEI EN 60228 (Tab. 9)
Rated voltage Uo/U: 300/500 V
Max. voltage: 550 V
Testing voltage: 2000 V
Max working temperature: 70 °C
Short-circuit temperature: 160 °C
Min installation temperature: 0 °C
Bending radius: Ø x 8
Max standard twisting (2x cable): ≥ 10 twists/meter
REGOLATION (UE) 305/2011
AVCP System: 1+ EN 50575:2014 + A1:2016
Classification : Cca-s3,d1,a3 UNI EN 13501-6
Cca : Heat release and flame spread(FS ≤ 2m) EN 50399
s3 : Smoke production (not s1 or s2) EN 50399
d1 : No flaming droplets/particles persisting longer than 10 s EN 50399
a3 : Gas acidity (not a1 or a2) EN 50267-2-3
Flame propagation (H ≤ 425 mm) EN 60332-1-2
Printing: BERICA CAVI S.P.A. ITALY FS18OHH2R18 300/500V CEI UNEL 35722 Cca-s3,d1,a3 CE Type -Year/Lot - 00000 m

TYPE
N° x mm2
MEDIUM Ø OUTER
mm
MEDIUM WEIGHT
kg/km
PRODUCT CODE
2x0,505,638B07C02050
3G0,505,847B07C03050
4G0,56,356B07C04050
5G0,56,865B07C05050
7G0,57,585B07C07050
10G0,59,2118B07C10050
12G0,59,6133B07C12050
14G0,510,3156B07C14050
16G0,510,8173B07C16050
19G0,511,3197B07C19050
24G0,513,0248B07C24050
27G0,513,6273B07C27050
2x0,756,046B07C02075
3G0,756,255B07C03075
4G0,756,970B07C04075
5x0,757,584B07C05075
7G0,758,1106B07C07075
10G0,7510,2153B07C10075
12G0,7510,6172B07C12075
14G0,7511,1194B07C14075
16G0,7511,9225B07C16075
19G0,7512,5256B07C19075
24G0,7514,5332B07C24075
27G0,7515,2365B07C27075
2x16,453B07C02100
3G16,767B07C03100
4G17,484B07C04100
5G18,0100B07C05100
7G18,9131B07C07100
10G111,0 183B07C10100
12G111,5211B07C12100
14G112,2243B07C14100
16G112,8271B07C16100
19G113,8322B07C19100
24G115,7402B07C24100
27G116,4444B07C27100
2x1,57,066B07C02150
3G1,57,382B07C03150
4G1,57,9102B07C04150
5G1,58,8127B07C05150
7G1,59,5162B07C07150
10G1,511,9231B07C10150
12G1,512,5266B07C12150
14G1,513,4311B07C14150
16G1,514,1353B07C16150
19G1,515,0412B07C19150
24G1,517,2517B07C24150
27G1,518,0572B07C27150
2x2,58,7103B07C02250
3G2,59,1132B07C03250
4G2,59,9164B07C04250
5G2,511,0201B07C05250

Berica Cavi Spa reserves the right to edit all the information on the website without providing prior notice to customers and / or users