SPECIAL ELECTRIC CABLES

INSTRUMENTATION CABLES ACCORDING TO MONTEDISON RULES

Technical Features

Cores colour code:   UNEL 00722 (Tab. 8) rule
Twisted cables pair or triads: Pair: black numbered - blue     Triads: black numbered - blue - brown  
Conductors: fine wires standed of bare copper CEI EN 60228 Cl.5 (Tab. 9) rule
Insulation: R2 quality PVC CEI 20-11 - CEI EN 50363 rules
Assembling pairs/triads by polyester tape helically wound MEU rule
Shielding pairs/triads: by aluminium/polyester tape helically wound MEU rule
Drain wires of pairs/triads: stranded tinned copper drain wire 7 x 0,30 mm MEU rule
Assembling by polyester tape helically wound MEU rule
Shield: by aluminium/polyester tape helically wound MEU rule
Drain wires: stranded tinned copper drain wire 7 x 0,30 mm MEU rule
Inner sheath: natural PVC  
Armour: steel wires braid / steel wires with steel tape CEI 20-14 rule
Outer sheath: Rz quality PVC CEI 20-11 - CEI EN 50363 rules
Sheath colour code: Blue RAL 5015 / Black RAL 9005 / Green RAL 6018  
Flame retardant test:   CEI 20-22/2 rule
Hidrocarbon resistance:   ENI 0.181.00 / CEI 20-34/0-1 rules
Electric resistance: acoording to CEI EN 60228 (Tab. 9) rule
Outer printing: BERICA CAVI S.P.A. (VI) CEI 20-22 II CE Year/Lot  - Initials MEU code - Progr. metric  
Bending radius: cabl outer diameter x 6/8  

---------

Web Design by EDIGRAF srl