| Cores colour code: | 1 couple: red-blue 2 couple: grey-yellow 3 couple: green-brown 4 couple: white-black | |
| Conductors: | bare copper | CEI EN 60228 Cl.5 (Tab 9) rule |
| Insulation: | fire resistant silicon rubber | |
| Flame barrier: | glass tape | |
| Drain wire: | tinned copper | |
| Shield: | aluminium/polyester tape | |
| Outer sheat: | LSOH termoplastic material M1 quality | CEI 20-11 - CEI EN 50363 rules |
| Outer shet colour: | red RAL 3000 | |
| Flame retardant test: | on single conductor or insulated cable | CEI EN 60332-1-2 rule |
| Smoke density: | emitted during the combustion | CEI EN 61034-2 rule |
| Fire resistant test: | 120 minutes at temperature of 830 °C | CEI EN 50200, DIN VDE 4102-12 E30/E60/E30, Warringtonfire n. 177607 14/11/08 (2x2x0,80) rules |
| Working voltage: | 300/500 V | |
| Electric resistance: | CEI EN 60228 (Tab 9) rule | |
| Testing voltage core/core: | 2000 V x 5’ | |
| Testing voltage core/shield in H2O: | 4000 V x 1’ | |
| Capacity core/core: | < 100 pF/m a 10 kHz | |
| Inductance: | < 0,85 µH/m a 10 kHz | |
| Working temperature: | (- 40 °C ÷ + 90 °C) | |
| Short-circuit emperature: | 350 °C | |
| Outer printing: | BERICA CAVI S.P.A. (VI) DIN VDE 4102-12 CE JE-H(St)H - EUROSAFE FE 180 - 300/500 V - PH120 2x2x0.80 mm - Year/Lot - Progr. Metric | |
| Bending radius: | minumun 15 times outer diameter |
| TYPE | MEDIUM Ø OUTER | MEDIUM WEIGHT | ITEM CODE |
|---|---|---|---|
| nr. x mm² | mm | kg x km |
| 1x2x0,80 | 6,1 | 50 | B7301C080FR |
| 2x2x0,80 | 9,1 | 100 | B7302C080FR |
| 3x2x0,80 | 9,7 | 115 | B7303C080FR |
| 4x2x0,80 | 11,3 | 145 | B7304C080FR |
---------
Web Design by EDIGRAF srl